LYR-3

Compact Freeze Dryer

A 3 kg / 24 h benchtop freeze drying platform for entry laboratory work and flask drying.

LabLyro LYR-3 Compact Freeze Dryer
Commercial model LYR-3 · Manufacturing reference: Pioneer 3 L platform
Nominal capacity
3 kg / 24 h
Loading format
4-tier rack option
Condenser
-60 / -85 / -105 C
Shelf / chamber
Tray or manifold

Application fit

Designed for entry laboratory work and flask drying

The LYR-3 is configured around the material, container or tray loading pattern rather than a generic chamber-volume claim. During selection, we review the frozen water load, expected sublimation rate, product thickness, working pressure and available utilities.

The published capacity is a selection reference. Actual throughput varies with formulation, water content, loading depth, freezing method, endpoint and the time reserved for loading, defrost and cleaning.

Published engineering reference

Commercial modelLYR-3
Manufacturing platformPioneer 3 L platform

These values trace to the Pioneer 3 L platform manufacturing platform. Final electrical, dimensional and performance details are confirmed in the approved project specification.

Configuration review

Available configuration work can include chamber accessories, shelf format, vacuum instrumentation, condenser temperature, pump arrangement, control recipes, data export, electrical standard and documentation. Final specifications are confirmed in the quotation and approved technical agreement.

Configuration matrix

Options reviewed for the LYR-3

These are engineering review categories, not a claim that every option is included in the base configuration.

Review itemHow it is configured
Condenser configuration-60 / -85 / -105 C; final temperature and capacity are selected around water or solvent behavior.
Sample accessoriesTray racks, vial shelves, stoppering, manifolds, flasks and chamber formats are reviewed for the actual workload.
Vacuum measurementPump arrangement, sensors, isolation and optional pressure-control instrumentation are selected with the method.
Scale-up and recordsLoading maps, recipes, temperature and pressure trends are organized for run comparison and process transfer.
Electrical standardVoltage, phase, frequency and connected load are confirmed for the installation country and approved configuration.
Controls and dataRecipe control, trend viewing, data export and remote-support scope are reviewed against the project.

From inquiry to delivery

A four-step equipment purchase path

Price and schedule become meaningful after the application and machine boundary are clear.

  1. 01

    Send the real workload

    Product, load, format, endpoint, cycles, utilities, country and timing.

  2. 02

    Review application and model

    Compare capacity, condenser, loading architecture, options and site interfaces.

  3. 03

    Approve the commercial file

    Confirm quotation, technical agreement, drawings, documentation, warranty and delivery terms.

  4. 04

    Build, test and hand over

    Complete the agreed FAT, export packing, shipment, commissioning and training scope.

Commercial confidence

What is defined before an order moves forward

No invented stock, delivery date or universal performance promise. The commercial file connects the machine to an approved technical basis.

01

Traceable model identity

LYR-3 / Pioneer 3 L platform remains visible from quotation and technical agreement through manuals, spare parts and service.

02

Approved specification

Capacity, utilities, interfaces, options and acceptance conditions are recorded before manufacturing release.

03

Factory acceptance

The agreed FAT scope can cover dimensions, controls, alarms, refrigeration, vacuum and documentation checks.

04

Export and delivery plan

Packing, shipping terms, lead time, installation access and site responsibilities are confirmed in the quotation.

05

Commissioning support

Remote support is standard; qualified projects can include on-site installation, commissioning and operator training.

06

Warranty and spare parts

Warranty scope, exclusions, service route, consumables and recommended spare parts are stated in the commercial file.

Continue the technical review

Related solutions, guides and evidence

Search all LYR-3 resources →

Product questions

LYR-3 quotation and configuration FAQ

Is the published 3 kg / 24 h capacity guaranteed for every product?

No. It is a model-selection reference. Product composition, frozen water, layer or fill depth, container, endpoint and full cycle schedule determine practical throughput.

Which configuration choices are available for the LYR-3?

The chamber or loading format, condenser, vacuum arrangement, controls, electrical standard, documentation and project options are reviewed around the Pioneer 3 L platform manufacturing platform.

What information is needed for a technical quotation?

Send the product or formulation, load per batch or per day, container or tray dimensions, target endpoint, operating schedule, installation country, utilities and required delivery window.

How are price, lead time and warranty confirmed?

They are stated in the project quotation after the configuration and commercial scope are reviewed. The approved technical agreement takes priority over general website information.

Related models

Compare nearby capacity points

Application review

Review the LYR-3 for your process.

Share the product, batch size, container, utilities and expected production rhythm. An engineer will recommend a practical starting configuration.

Request model guidance
WhatsApp